PTD · Secondary systems for substations and switchgear

Engineering for substations and switchgear – standards-compliant, consistent, from one data basis

For municipal utilities and grid operators who no longer want to search for their substation documentation in folders, but want to have it under control at a glance.

Symbolic diagram of a substation feeder bay: double busbar with busbar disconnectors -QB1 and -QB2, bypass -QB7, circuit breaker -QA1, earthing switches -QC1 and -QC9, instrument transformer set -BZ1 with five current transformers and one voltage transformer, outgoing disconnector -QB9 and cable outlet.M-QB14000AM-QB24000AM-QB74000A-QC1M-QA14000A2000/1A ext 200%2000/1A ext 200%2000/1A ext 200%2000/1A TPZ Icth=200%2000/1A TPZ Icth=200%P1P2-BZ1[Imax 1200A]M-QB94000AM-QC9400√3/0,1√3/0,1√3/0,1√3kV

Grid operators face two tasks at once. Existing substations have grown over decades and their documentation is inconsistent. At the same time, the number of new-build and conversion projects is rising due to grid expansion and the energy transition. TechnologiX takes care of both. We transfer your existing secondary systems documentation into Engineering Base and bring it up to the actual as-built state. For new builds and conversions, we design the secondary systems from the circuit diagram to the wiring diagram of the protection cabinet. Everything is created in line with the standards and in one shared data model that you use throughout the entire life cycle of your plants.

Diagram: protection cabinet in bay =E02+S1 with distance protection -FA1 and bay control unit -KF1. Both are wired to terminal strip -X1, from which control cables -W12 and -W13 lead off. The bay control unit is connected to the IEC 61850 station bus.=E02+S1-FA1Distance protection-KF1Bay control unitStation busIEC 61850-X1-W13-W12Control cables

Every device, every terminal, every cable

carries its designation in accordance with IEC 81346. Protection devices, terminal strips, control cables and the control system all access the same data.

A protection device is replaced? The terminal diagram, device list and cable list show the new status immediately.

Why municipal utilities work with TechnologiX

  • Close by

    With two offices in northern Germany (Wardenburg and Kiel), we are quickly on site, for surveys in the substation as well as for meetings with your specialist department.

  • Short paths

    You talk directly to the engineers who design your plants. There are no corporate channels and no changing contacts.

  • Specialists, not generalists

    Together, our team brings more than 20 years of experience with Engineering Base.

  • Vendor-independent

    Our advice is independent of specific protection device or control system manufacturers.

We also take on engineering packages for transmission system operators and large grid companies, for example as a permanently integrated partner in expansion programmes.

Our services

From transferring your existing documentation to complete engineering of the secondary systems.

  1. Transferring existing documentation into Engineering Base

    Many municipal utilities know the situation: circuit diagrams from different CAD generations, red-line mark-ups on paper, terminal diagrams as scans. TechnologiX turns this into a reliable as-is status.

    • Review and assessment of the existing substation and secondary systems documentation
    • Data migration from legacy systems and formats such as ELCAD, RUPLAN and PDF
    • On-site as-built reconciliation: we compare the documentation with what is actually installed.
    • Incorporation of red-line mark-ups and undocumented changes
    • Uniform structuring and equipment designation across all substations
  2. Project control, tendering and award

    • Project management and engineering management for new-build and conversion projects
    • Enquiry and tender specifications for protection and control, control cabinets and devices
    • Technical evaluation of offers as a basis for the award decision
    • Bills of quantities for installation and commissioning
  3. Secondary systems for new builds and conversions

    • Circuit diagrams and schematic documents for the secondary systems
    • Functional descriptions for protection, control and interlocking functions
    • Terminal and wiring diagrams for protection, control and automation cabinets
    • Device and terminal lists
    • Cable lists and cable plans, including cable tray planning in the 3D model
    • Design of low-voltage power distribution, e.g. for the station auxiliary supply
    • Control cabinet design as manufacturing documents for the panel builder
    • Typical-based design for recurring bays, protection and control cabinets and substation types
    • Conversion planning during operation: we document interim states and construction phases traceably.
    • Support with commissioning and site supervision
  4. Protection and control in accordance with IEC 61850

    In digital substations, hardware design and control system configuration are closely intertwined. We design both together.

    • Definition of protection and control in accordance with IEC 61850 in the same data model as the secondary systems hardware
    • Standards-compliant plant description as the basis for configuring protection and control
    • A continuous chain from circuit diagram to device configuration, without manual transfer between tools
  5. Standards-compliant structure as a quality foundation

    Standards ensure that your documentation is still readable in 30 years, including by third parties. We apply them consistently:

    • IEC 81346Plant structure and reference designation (function-, product- and location-oriented)
    • IEC 81355Classification and designation of documents and information (successor to IEC 61355)
    • IEC 61082Standards-compliant structure of electrotechnical documents
    • IEC 61850Description and communication of protection and control
    • On request, we implement your company's internal designation guidelines, in addition to or building on the standards.
  6. Operation and maintenance

    • Ongoing updating of the documentation when the grid changes
    • Modifications, functional extensions and minor conversions, e.g. new feeders, protection device replacement or control system retrofit
    • Provision of up-to-date documents for inspections, maintenance and fault clearance
    • Provision of plant data for your maintenance and servicing systems

Single source of truth: one data backbone for the entire substation

In many grid companies, secondary systems and protection and control work in separate tools with separate data sets. Every interface between these worlds is a source of error. A protection device is replaced, but the terminal list stays outdated. A cable is rerouted, but the wiring diagram still shows the old route.

TechnologiX brings these disciplines together in one data model. The disciplines continue to work separately, but they work on shared data:

  • One object, one truth: each piece of equipment exists exactly once. Circuit diagram, terminal diagram, device list, cable list and control system configuration all access the same object.
  • Changes take effect everywhere: if a piece of equipment changes, all affected documents see the new status immediately.
  • Information doesn't become outdated: your documentation is a maintained data basis that grows with the plant, not a folder in the archive.
  • A digital twin over the entire life cycle: from initial planning through construction and commissioning to maintenance decades later.

We don't produce dead documents, we maintain living databases. The documents are outputs from this data basis, in the format that you, your inspectors or your contractors need.

Quality assurance: documentation that stands up to inspection

In grid operation, the documentation must be right, for operational safety, for switching-authorised personnel and for auditors. That is why quality assurance is an integral part of our process and not a check added at the end.

How every change is handled
  1. RecordWho changes what and why
  2. ImpactAffected documents and cabinets
  3. CheckFour-eyes principle or your rules
  4. ReleaseUnique revision index
  5. ReconcileDocumented equals installed
  • Revision and change management: for every change, it is traceable who made it, when and why.
  • Review and release workflows: changes only take effect after a defined review, according to the four-eyes principle or your internal release rules.
  • Consistent versioning: every status has a unique revision index. Earlier states remain retrievable.
  • Impact analysis: before a change, we show which documents, cabinets and disciplines are affected, so nothing is forgotten.
  • Reconciling documentation and reality: regular as-built reconciliation ensures that the documented status matches what is actually installed.
  • Standards-compliant designation: uniform structures in accordance with IEC 81346 make the documentation readable and verifiable for any qualified person.

The result is documentation that is technically correct and can be verified traceably at any time.

Typical assignments

Example sequences, not specific client projects.

Reworking the secondary systems documentation of a municipal utility

Starting point
Several substations have been documented by different designers over decades. Designations, document revisions and CAD formats are inconsistent.
Approach
We migrate the legacy data into Engineering Base and reconcile it on site with what is installed. We then structure all substations uniformly in accordance with IEC 81346.
Result
The utility has a reliable as-is status of all substations as the basis for future conversions. The data remains maintained and does not become outdated again.

New substation

Starting point
A grid operator is planning a new substation with digital protection and control.
Approach
We take on the consistent engineering of the secondary systems, from the circuit diagrams to the terminal and wiring diagrams of the protection cabinets. We define the control system in line with IEC 61850 in the same data model.
Result
Cabinet wiring and control system fit together seamlessly, without data gaps between design tools. From commissioning onwards, the documentation can be used directly as operating documentation.

Quality assurance during grid operation

Starting point
Changes to substations are carried out, but not always documented promptly or completely.
Approach
We set up a regulated change process with a review and release workflow and, on request, take over the ongoing updating.
Result
Every grid change is documented traceably and in an audit-proof manner. Switching-authorised personnel always work with the current status.

Standardisation for many similar substations

Starting point
A municipal utility operates a large number of substations or bays with a similar design.
Approach
We define reusable typicals for recurring bay and cabinet types and design new substations on this basis.
Result
New substations are designed faster, the error rate falls, and all substations are built and documented uniformly.

Frequently asked questions about PTD and substations

What does TechnologiX do for substations and switchgear?

TechnologiX GmbH transfers the existing secondary systems documentation of municipal utilities and grid operators into Engineering Base and brings it up to the actual as-built state. For new builds and conversions, TechnologiX designs the secondary systems and the protection and control from the circuit diagram to the wiring diagram of the protection cabinet, in line with the standards and in one shared data model.

Can TechnologiX transfer ELCAD and RUPLAN data into Engineering Base?

Yes. TechnologiX GmbH migrates substation and secondary systems documentation from legacy systems and formats such as ELCAD, RUPLAN and PDF into Engineering Base. This includes on-site as-built reconciliation, incorporating red-line mark-ups and undocumented changes, and uniform equipment designation across all substations.

Which standards does TechnologiX apply to secondary systems?

TechnologiX GmbH structures substation documentation in accordance with IEC 81346 (plant structure and reference designation), IEC 81355 (classification of documents, successor to IEC 61355), IEC 61082 (structure of electrotechnical documents) and IEC 61850 (protection and control). On request, TechnologiX also implements company-specific designation guidelines.

Does TechnologiX design protection and control in accordance with IEC 61850?

Yes. TechnologiX GmbH defines protection and control in accordance with IEC 61850 in the same Engineering Base data model as the secondary systems hardware. This creates a continuous chain from the circuit diagram to the device configuration, without manual transfer between tools.

Is TechnologiX tied to specific protection device or control system manufacturers?

No. TechnologiX GmbH advises on secondary systems and protection and control independently of specific protection device or control system manufacturers.

How does TechnologiX assure the quality of substation documentation?

At TechnologiX GmbH, quality assurance is an integral part of the process. It includes revision and change management, review and release workflows according to the four-eyes principle or your own rules, consistent versioning with a unique revision index, an impact analysis before every change and regular reconciliation of documentation with what is actually installed.

How up to date is your substation documentation really?

Together with you, we take a look at one of your substations and show you what the path to a maintained, standards-compliant data basis looks like. The meeting is non-binding, and we come to you.

Arrange a review meeting